Fluke 107 multimeter: specs

Palm-sized 6000-count digital multimeter for voltage, current to 10 A, resistance, capacitance, frequency, duty cycle and diode test. Rated CAT III 600 V by Fluke.

Every value cites its sourcePinout not published

Buy on Compoden

Specs

SpecValueSource
DC voltage6.000 V, 60.00 V, 600.0 V; accuracy 0.5 % + 3source
Accuracy Specifications (p.28)
AC voltage6.000 V, 60.00 V, 600.0 V (40 Hz to 500 Hz); 1.0 % + 3source
Accuracy Specifications (p.28)
Current4.000 A and 10.00 A, AC (40 Hz to 200 Hz) and DC; 1.5 % + 3; 10 A duty cycle under 7 minutes on, 20 minutes off at 25 C to 40 Csource
Accuracy Specifications (p.31)
Resistance400.0 ohm to 40.00 Mohm; 0.5 % + 3 to 1.5 % + 3 by rangesource
Accuracy Specifications (p.29)
Capacitance50.00 nF to 1000 uF; 2 % + 5 (nF ranges), 5 % + 5 (uF ranges)source
Accuracy Specifications (p.29)
Frequency50.00 Hz to 100.0 kHz (10 Hz to 100 kHz); 0.1 % + 3source
Accuracy Specifications (p.30)
SafetyIEC 61010-2-033 CAT III 600 V; 600 V maximum between any terminal and earth ground; A input fuse 11 A, 1000 Vsource
General Specifications (p.25-27)
Display6000 counts, updates 3 per secondsource
General Specifications (p.25)
Battery2 AAA (IEC LR03), 200 hours minimumsource
General Specifications (p.25)
Operating temperature0 C to 40 C (storage -30 C to 60 C)source
General Specifications (p.25-26)

Power

ValueSource
Supply2 x AAA cellssource
General Specifications (p.25)
Current200 hours minimum battery lifesource
General Specifications (p.25)

Pinout

We don't publish a pin table for this part: no official source we could verify gives one. Check the labels printed on your module, and see the notes below.

A meter has no header; see the Fluke 106/107 users manual for jack positions.