soldr.ai

Docs  /  Components

PZEM-004T AC energy monitor: specs

A single-phase AC measurement module for voltage, current, active power, frequency, power factor and energy; the 100A version uses an external current transformer. It connects to mains. The maker page title for the series says 'TTL Modbus'. Figures below are from the maker's PZEM-004T product page.

Every value cites its sourcePinout not published

Buy on Compoden

Specs

SpecValueSource
Voltage measuring range80 V to 260 V, resolution 0.1 V, accuracy 0.5 %source
Product description, Measurement range
Current measuring range (100A model)0 to 100 A with an external transformer; starting current 0.02 A; resolution 0.001 A; accuracy 0.5 %source
Product description, Measurement range
Active power range (100A model)0 to 23 kW; starting power 0.4 W; resolution 0.1 W; accuracy 0.5 %source
Product description, Measurement range
Active energy0 to 9999.99 kWh, resolution 1 Wh, accuracy 0.5 %; reset by softwaresource
Product description, Measurement range
Frequency45 Hz to 65 Hz, resolution 0.1 Hz, accuracy 0.5 %source
Product description, Measurement range
Power factor0.00 to 1.00, resolution 0.01, accuracy 1 %source
Product description, Measurement range
CommunicationTTL interface over UART: 9600 baud, 8 data bits, 1 stop bit, no paritysource
Product description, Communication interface and Physical layer protocol

Pinout

We don't publish a pin table for this part: no official source we could verify gives one. Check the labels printed on your module, and see the notes below.

The maker page does not list terminals or header pins. Mains terminals and the TTL header are not documented here.

Build with it

Project ideas for the PZEM-004T AC energy monitor. Each link opens Soldr with the prompt filled in; Soldr assigns the pins, checks power and shows how to wire every part.

Common mistakes

Not covered by the official source