# Water turbidity sensor: specs

> Optical turbidity probe with an amplifier board that gives an analog voltage, and a digital high/low output with an adjustable threshold. Every spec…

[HTML version](https://soldr.ai/docs/components/turbidity-sensor)

[Docs](https://soldr.ai/docs) / [Components](https://soldr.ai/docs/components)

Optical turbidity probe with an amplifier board that gives an analog voltage, and a digital high/low output with an adjustable threshold. Every spec below is from the original maker&#x27;s SEN0189 wiki, a reference board: the stocked board is not confirmed to be that board, so its supply, output range and digital output are not confirmed.

Every value cites its sourcePinout not published

[Buy on Compoden](https://compoden.com/products/water-turbidity-sensor-with-analog-module-ntu-measurement)

## Specs

| Spec | Value | Source |
|---|---|---|
| the original maker&#x27;s SEN0189 reference board: Operating voltage | 5 V DC | source Specification table (wiki page for SEN0189) |
| the original maker&#x27;s SEN0189 reference board: Operating current | 40 mA max | source Specification table (wiki page for SEN0189) |
| the original maker&#x27;s SEN0189 reference board: Response time | under 500 ms | source Specification table (wiki page for SEN0189) |
| the original maker&#x27;s SEN0189 reference board: Insulation resistance | 100 Mohm min | source Specification table (wiki page for SEN0189) |
| the original maker&#x27;s SEN0189 reference board: Analog output | 0 to 4.5 V | source Specification table (wiki page for SEN0189) |
| the original maker&#x27;s SEN0189 reference board: Digital output | High/Low level; threshold adjustable with the potentiometer | source Specification table (wiki page for SEN0189) |
| the original maker&#x27;s SEN0189 reference board: Operating temperature | 5 C to 90 C | source Specification table (wiki page for SEN0189) |
| the original maker&#x27;s SEN0189 reference board: Storage temperature | -10 C to 90 C | source Specification table (wiki page for SEN0189) |
| the original maker&#x27;s SEN0189 reference board: Weight | 30 g | source Specification table (wiki page for SEN0189) |

## Power

| | Value | Source |
|---|---|---|
| Supply | the original maker&#x27;s SEN0189 reference board: 5 V DC (stocked board&#x27;s supply not confirmed) | source Specification table |
| Current | the original maker&#x27;s SEN0189 reference board: 40 mA max (stocked board not confirmed) | source Specification table |

## Pinout
We don't publish a pin table for this part: no official source we could verify gives one. Check the labels printed on your module, and see the notes below.

The the original maker&#x27;s wiki is used as the reference for this module type. The pin labels of the board you receive are not confirmed by a document, so read the markings printed on it.

## Build with it
Project ideas for the Water turbidity sensor. Each link opens Soldr with the prompt filled in; Soldr assigns the pins, checks power and shows how to wire every part.

- [Water clarity display](https://app.soldr.ai/?prompt=I%20want%20to%20build%20a%20water%20clarity%20display%20with%20an%20Arduino%20Uno%2C%20a%20turbidity%20sensor%20module%20and%20a%2016x2%20I2C%20LCD): On the original maker&#x27;s reference board the supply is 5 V and the analog output runs to 4.5 V, which an Uno input accepts; measure the output of the board you received before relying on that. Relative readings only; not a drinking-water test. Learning project.
- [Finer-resolution turbidity reading](https://app.soldr.ai/?prompt=I%20want%20to%20build%20a%20turbidity%20reader%20with%20an%20Arduino%20Uno%2C%20a%20turbidity%20sensor%20module%2C%20an%20ADS1115%20converter%20and%20an%20OLED%20display): On the reference board the output reaches 4.5 V, so power the converter at 5 V to keep it within its supply; measure the output of the board you received before connecting it to the converter. Learning project.
- [Aquarium clarity log](https://app.soldr.ai/?prompt=I%20want%20to%20build%20a%20turbidity%20logger%20with%20an%20Arduino%20Uno%2C%20a%20turbidity%20sensor%20module%2C%20a%20real%20time%20clock%20and%20a%20microSD%20card%20reader): Logs a time-stamped reading to compare water clarity over days. Learning project.

## Common mistakes

- Feeding the analog output straight into a 3.3 V ADC pin: the analog output runs to 4.5 V and the supply is 5 V ([source](https://wiki.dfrobot.com/sen0189/))
- Using it as a calibrated NTU meter: the fetched wiki page lists no voltage-to-NTU table, so readings are only relative until you calibrate against a known standard ([source](https://wiki.dfrobot.com/sen0189/))
- Running it outside 5 C to 90 C: the stated operating range is 5 C to 90 C ([source](https://wiki.dfrobot.com/sen0189/))

## Not covered by the official source

- Listing product is not confirmed identical to the original maker&#x27;s SEN0189; values are that board&#x27;s published specification.
- The the original maker&#x27;s wiki gives no pin table or voltage-to-NTU curve; both are omitted.
- Probe waterproof depth and probe cable length are not stated.
- No voltage-to-NTU table is published for this board, so readings are relative until you calibrate.

## Sources

- [link](https://wiki.dfrobot.com/sen0189/) (the original maker&#x27;s wiki, Gravity: Analog Turbidity Sensor for Arduino, SEN0189; maker page, retrieved 2026-11-07)